Table #2 - Drawdown Factors
Close Table
Maximum System Pressure
(cut-out) PSIG / (kPa) / bar |
Mimimum System Pressure (cut-in) -- PSIG / (kPa) / bar |
20
(138)
1.38 |
25
(173)
1.72 |
30
(207)
2.06 |
35
(242)
2.41 |
40
(276)
2.76 |
45
(311)
3.10 |
50
(345)
3.45 |
55
(380)
3.80 |
60
(414)
4.16 |
65
(449)
4.48 |
70
(483)
4.83 |
75
(518)
5.17 |
80
(552)
5.51 |
85
(587)
5.86 |
90
(621)
6.20 |
95
(656)
6.55 |
100
(690)
6.89 |
105
(725)
7.24 |
110
(759)
7.58 |
| 30 / (207) / 2.06 |
0.21 |
| 35 / (242) / 2.41 |
0.28 |
0.19 |
| 40 / (276) / 2.76 |
0.34 |
0.26 |
0.17 |
| 45 / (311) / 3.10 |
0.39 |
0.32 |
0.24 |
0.16 |
| 50 / (345) / 3.45 |
0.44 |
0.37 |
0.30 |
0.22 |
0.15 |
|
| 55 / (380) / 3.80 |
0.47 |
0.41 |
0.34 |
0.28 |
0.21 |
0.14 |
| 60 / (414) / 4.16 |
0.50 |
0.44 |
0.38 |
0.32 |
0.26 |
0.19 |
0.13 |
| 65 / (449) / 4.48 |
0.53 |
0.48 |
0.42 |
0.36 |
0.30 |
0.24 |
0.18 |
0.12 |
| 70 / (483) / 4.83 |
0.56 |
0.50 |
0.45 |
0.40 |
0.34 |
0.29 |
0.23 |
0.17 |
0.11 |
| 75 / (518) / 5.17 |
|
0.53 |
0.48 |
0.43 |
0.38 |
0.32 |
0.27 |
0.22 |
0.16 |
0.11 |
|
| 80 / (552) / 5.51 |
|
|
0.50 |
0.46 |
0.41 |
0.36 |
0.31 |
0.26 |
0.21 |
0.15 |
0.10 |
| 85 / (587) / 5.86 |
|
|
|
0.48 |
0.43 |
0.39 |
0.34 |
0.29 |
0.24 |
0.20 |
0.15 |
0.10 |
| 90 / (621) / 6.20 |
|
|
|
|
0.46 |
0.42 |
0.37 |
0.32 |
0.28 |
0.23 |
0.19 |
0.14 |
0.09 |
| 95 / (656) / 6.55 |
|
|
|
|
|
0.44 |
0.40 |
0.35 |
0.31 |
0.27 |
0.22 |
0.18 |
0.13 |
0.09 |
| 100 / (690) / 6.89 |
|
|
|
|
|
|
0.42 |
0.38 |
0.34 |
0.30 |
0.26 |
0.21 |
0.17 |
0.13 |
0.09 |
|
| 105 / (725) / 7.24 |
|
|
|
|
|
|
|
0.41 |
0.37 |
0.33 |
0.29 |
0.25 |
0.20 |
0.16 |
0.13 |
0.08 |
| 110 / (759) / 7.58 |
|
|
|
|
|
|
|
|
0.39 |
0.35 |
0.31 |
0.27 |
0.24 |
0.20 |
0.16 |
0.12 |
0.08 |
| 115 / (794) / 7.92 |
|
|
|
|
|
|
|
|
|
0.38 |
0.34 |
0.30 |
0.26 |
0.23 |
0.19 |
0.15 |
0.11 |
0.08 |
| 120 / (828) / 8.27 |
|
|
|
|
|
|
|
|
|
|
0.36 |
0.33 |
0.29 |
0.25 |
0.22 |
0.18 |
0.15 |
0.11 |
0.07 |
| 125 / (863) / 8.62 |
|
|
|
|
|
|
|
|
|
|
|
0.35 |
0.32 |
0.28 |
0.25 |
0.21 |
0.18 |
0.14 |
0.11 |
In keeping with current industry standards, drawdown factors are based on Boyles law. Actual drawdowns will vary depending upon system variables including the accuracy and operation of the pressure switch and gauge, actual precharge pressure, and operating temperature of the system.
Close Table |
|
 |
|
|