Go to Home Page Go to Links Go to Products Technical Information Go to FAQ's Access Our Literature Contact Us Distributor Locator
Technical
Residential Tank Sizing Calculator | Tank Replacement Guides
Tank Sizing Calculator
Basic sizing and selection requirements

There are three factors to consider when selecting the proper size WellMate for your Water system:
  • The pump delivery rate in gallons/liters per minute (GPM/LPM)
  • The recommended minimum running time of the pump
  • The minimum (cut-in) and maximum (cut-out) system pressure parameters

Once these factors are known, the following calculations will determine, in most cases, the correct model to meet your specifications.*

Step 1: Calculate Drawdown
  1. Pump delivery rate in GPM/LPM
    GPM/LPM
  2. Desired minimum pump running time in minutes
    (1 minute, 45 seconds = 1.75 minutes)
    Minutes
  3. Click "Calculate Drawdown". This is the minimum drawdown or available water volume required in Gallons/Liters.*

    Gallons/Liters.
Step 2: Calculate Tank Size
  1. Minimum system pressure (cut-in)
    PSIG/kPa/bar
  2. Maximum system pressure (cut-out)
    PSIG/kPa/bar
  3. Using table #2 (click here), find the drawdown factor applicable to lines #4 and #5.
    Factor
  4. I need a Low-Profile Tank (for small spaces like a crawl space or under a mobile home)
  5. Select to calculate in gallons or liters



  6. This is the WellMate model we recommend based on your entries.
    Model Number:
     


* If a volume of water needed is greater than the amount calculated on line #3, enter that amount on line #3 in place of the calculated volume.


See complete Model & Spec list below for other tank options.

Specifications

WM Performance Data
Model Number Capacity
gal / liter
Maximum
Operating Pressure
psi / kPa / Bar
Drawdown
30/50 Setting**
gal / liter
Diameter*
inch
/ cm
Overall Height*
inch / cm
Height* inlet/ outlet to floor
inch
/ cm
System
Connection
Assembly Weight*
lb / kg
Pallet
QTY.
WM-4 / WM0060
14.5 / 55 100 / 700 / 7.0 4.4 / 16.5 16 / 41 26 / 66 1 3/4 / 4.4 1" male NPT 14.5 / 6.6 9
WM-6 / WM0075
19.8 / 75 100 / 700 / 7.0 5.9 / 22.5 16 / 41 32 / 81 1 3/4 / 4.4 1" male NPT 17.75 / 8.1 9
WM-9 / WM0120
29.5 / 112 100 / 700 / 7.0 8.9 / 33.5 16 / 41 44 / 112 1 3/4 / 4.4 1" male NPT 24.75 /11.2 9
WM-12 / WM0150
40.3 / 153 100 / 700 / 7.0 12.1 / 45.8 16 / 41 57 / 145 1 3/4 / 4.4 1" male NPT 30 /13.6 9
WM-23 / WM0300
79.6 / 301 100 / 700 / 7.0 23.8 / 90.4 21 / 53 62 / 157 2 1/4 / 5.7 1 1/4" male NPT 65.7 / 29.8 4
WM-14WB / WM0180
47.1 / 178 125 / 862 / 8.6 14.1 / 53.5 21 / 53 41 1/4 / 105 2 1/4 / 5.7 1 1/4" male NPT 43 / 19.5 4
WM-20WB / WM0235
60.0 / 227 125 / 862 / 8.6 18.0 / 68.1 24 / 61 41 1/2 / 105 2 1/4 / 5.7 1 1/4" male NPT 50 /22.7 4
WM-25WB / WM0330
86.7 / 328 125 / 862 / 8.6 26.0 / 98.5 24 / 61 55 1/4 / 140 2 1/4 / 5.7 1 1/4" male NPT 72.75 / 33.0 4
WM-35WB / WM0450
119.7 / 453 125 / 862 / 8.6 35.9 / 135.9 24 / 61 74 1/4 / 189 2 1/4 / 5.7 1 1/4" male NPT 95 / 43.1 N/A

Low-Profile Performance Data
Model Number Capacity
gal / liter
Maximum
Operating Pressure
psi / kPa / Bar
Drawdown
30/50 Setting**
gal / liter
Diameter*
inch
/ cm
Overall Height*
inch / cm
Height* inlet/
outlet to floor
inch
/ cm
System
Connection
Assembly Weight*
lb / kg
Pallet
QTY.
WM-6LP / WM-LP-075 19.3 / 73 100 / 700 / 7.0 5.8 / 21.9 24 / 61 20 1/4 / 51 2 1/4 /5.7 1" male NPT 22.75 / 10.3 8
WM-10LP / WM-LP-130 34.5 / 131 100 / 700 / 7.0 10.4 / 39.2 24 / 61 28 /71 2 1/4 /5.7 1" male NPT 29.5 / 13.4 8

Note: Maximum external operating temperature 120°F (49°C). Maximum internal operating temperature 100°F (38°C). Minimum operating temperature 40°F (4°C).

* Diameter, height and weight may vary slightly without notice.

** In keeping with current industry standards, drawdown factors are based on Boyle's law. Actual drawdowns will very depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.


WellMate Pentair Water, 220 Park Drive, Chardon, Ohio 44024 | 440-286-4116