See complete Model & Spec list below for other tank options.
WM Performance Data
Model Number
Capacity gal / liter
Maximum
Operating Pressure psi / kPa / Bar
Drawdown
30/50 Setting** gal / liter
Diameter*
inch / cm
Overall Height* inch / cm
Height* inlet/ outlet to floor
inch / cm
System
Connection
Assembly Weight* lb / kg
Pallet
QTY.
WM-4 / WM0060
14.5 / 55
100 / 700 / 7.0
4.4 / 16.5
16 / 41
26 / 66
1 3/4 / 4.4
1" male NPT
14.5 / 6.6
9
WM-6 / WM0075
19.8 / 75
100 / 700 / 7.0
5.9 / 22.5
16 / 41
32 / 81
1 3/4 / 4.4
1" male NPT
17.75 / 8.1
9
WM-9 / WM0120
29.5 / 112
100 / 700 / 7.0
8.9 / 33.5
16 / 41
44 / 112
1 3/4 / 4.4
1" male NPT
24.75 /11.2
9
WM-12 / WM0150
40.3 / 153
100 / 700 / 7.0
12.1 / 45.8
16 / 41
57 / 145
1 3/4 / 4.4
1" male NPT
30 /13.6
9
WM-23 / WM0300
79.6 / 301
100 / 700 / 7.0
23.8 / 90.4
21 / 53
62 / 157
2 1/4 / 5.7
1 1/4" male NPT
65.7 / 29.8
4
WM-14WB / WM0180
47.1 / 178
125 / 862 / 8.6
14.1 / 53.5
21 / 53
41 1/4 / 105
2 1/4 / 5.7
1 1/4" male NPT
43 / 19.5
4
WM-20WB / WM0235
60.0 / 227
125 / 862 / 8.6
18.0 / 68.1
24 / 61
41 1/2 / 105
2 1/4 / 5.7
1 1/4" male NPT
50 /22.7
4
WM-25WB / WM0330
86.7 / 328
125 / 862 / 8.6
26.0 / 98.5
24 / 61
55 1/4 / 140
2 1/4 / 5.7
1 1/4" male NPT
72.75 / 33.0
4
WM-35WB / WM0450
119.7 / 453
125 / 862 / 8.6
35.9 / 135.9
24 / 61
74 1/4 / 189
2 1/4 / 5.7
1 1/4" male NPT
95 / 43.1
N/A
Low-Profile Performance Data
Model Number
Capacity gal / liter
Maximum
Operating Pressure psi / kPa / Bar
Drawdown
30/50 Setting** gal / liter
Diameter*
inch / cm
Overall Height* inch / cm
Height* inlet/
outlet to floor
inch / cm
System
Connection
Assembly Weight* lb / kg
Pallet
QTY.
WM-6LP / WM-LP-075
19.3 / 73
100 / 700 / 7.0
5.8 / 21.9
24 / 61
20 1/4 / 51
2 1/4 /5.7
1" male NPT
22.75 / 10.3
8
WM-10LP / WM-LP-130
34.5 / 131
100 / 700 / 7.0
10.4 / 39.2
24 / 61
28 /71
2 1/4 /5.7
1" male NPT
29.5 / 13.4
8
Note: Maximum external operating temperature 120°F (49°C). Maximum internal operating temperature 100°F (38°C). Minimum operating temperature 40°F (4°C).
* Diameter, height and weight may vary slightly without notice.
** In keeping with current industry standards, drawdown factors are based on Boyle's law. Actual drawdowns will very depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.